OPM 100 Spectrophotometer
Water Solution
OPM 100 Spectrophotometer
Water Solution
- Solutions
- Water
- OPM 100 Spectrophotometer
OPM 100 Spectrophotometer
Reliable Analyser for Wastewater Quality Measurement
Download Brochure
The OPM 100 SERIES system is the ideal solution for accurately measuring Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), and Biochemical Oxygen Demand (BODc) online. The advanced OPRUSS Spectrophotometers are compact yet precise instruments suitable for various water types. They utilize innovative Dual Beam Absorption technology, which analyzes light absorption in both ultraviolet and visible ranges to detect contaminants.
Benefits
- Zero reagent use
- Capability for outdoor installation
- Effective operation in different water types, making it suitable for treated wastewater applications, where conditions can change and interferences can be high.
OPM OPTICAL SERIES
System This series offers precise measurements for treated wastewater from effluent and sewage treatment plants. With no need for consumables or chemicals, it allows accurate determination of COD and turbidity levels.
● Continuous operating application
● Non-interruptible stable output
● Adaptability to AUTOMATICA Two Way Diagnostics
● Ultra-efficient power consumption
● Spectral response range: 190 nm to 1100 nm
● High sensitivity across the complete spectral range
● Superiorly accurate performance
● Capability to transmit background data for interference cancellation
Measurement Method
UV + VIS Spectrophotometer (Dual Beam Absorption Spectrophotometry)
● Turbidity compensation at overlapping spectral bandwidth
Measured Parameters
● COD
● BODc
● TSS
Measurement Range with Maximum Accuracy
● COD: 0-2000 mg/l
● BODc: 0-2000 mg/l
● TSS: 0-2000 mg/l
Measurement Accuracy
● Within ± 5% of full scale
Measurement Repeatability
● Within ± 5% of full scale
Measurement Linearity
● Within ± 5% of full scale
Measurement Stability
● Within ± 5% of full scale
Measurement Interval
● T90 Data output within 1 minute
Resolution
● 0.1 mg/L
Calibration
● Multi-point based automatic calibration
● Standard calibration as per factory setting
● Local calibration for adaptive environments with respect to organic and inorganic proportions
Ingress Protection Class
● IP68 for Spectrophotometer analyser
Cleaning Method
● ACSC Cleaning
● Scheduled interval settable every 05 – 1200 minutes
● Can be triggered remotely
Material of Construction
● Titanium, POM, SS316L
Cable Length
● 10 m standard (expandable)
Sample Operating Pressure & Flow Rate
● 1 – 12 Bar / 0.5 – 20 LPM
Output
● RS485 from OPRUSS OPM100 Controller system
Sensor Diagnostics
● Sensor perform periodic self-tests to verify they are functioning correctly. This include checking internal temperature, ACSC Cleaning Functionality and connectivity.
● Ambient Temperature: 0-80 ̊C (subjected to non-freezing sample condition)
● Ambient Humidity: 90% RH
● Maximum Pressure: 12 bars
● Resistant to corrosive applications
Secondary Data
● Temperature compensation
● Lamp health
● Cleaning system health, and more
Construction
● Compatible for in-situ and extractive installation
Color/Finish
● Standard integral material finish as per MOC
Power Supply
● 12V DC
- Shell made of non-corrosive POM material.
- Built-in interference cancellation.
- Adaptability to different types of water.
- Grill casing for protection in surface water.
- Precise measurements without needing calibration.
- Maintenance-free cleaning system with self-cleaning features.
- Reliable performance in tough conditions
Self-cleaning systems prevent fouling from biofilm or particles, ensuring reliable performance.
Cleaning frequency can be adjusted as needed.
Installable in-place (in-situ) or as removable (extractive) installations.
- Sewage Treatment Plant
- Effluent Treatment Plant
- Water Treatment Plant
- Lake and River Monitoring
- Chemical Processing Plant