The OPRUSS series online gas detector uses a high-quality imported sensor and an ultra-low power 32-bit microprocessor. It has advantages such as high accuracy, good repeatability, stable signals, and quick response times. It can connect to various control systems, including PLCs, DCS, computers, and others. It also features remote monitoring, alarms, data logging, and analysis functions.
Common applications include gas safety inspections and alarms in industrial settings, such as petroleum refineries, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire safety, and environmental protection. It is used to monitor VOCs (volatile organic compounds) gas concentrations.
Measured Gas : | Volatile Organic Compounds |
Sensor Type : | PID (Photoionization) |
Sampling Way : | Diffusion, Pump (Pipeline) |
Detection Range : | 2/20/200/2000/10000 ppm |
Operating Temperature : | -10°C – 40°C |
Pressure Range : | 860 – 1060 hpa |
Accuracy : | 0.01 ppm, 0.1 ppm, 1 ppm |
Response Time : | IT90 < 30s (most) |
Input Power : | 9-24 VDC |
Current Consumption : | 20-200 MA |
Alarm Error : | < + 10% alarm set value |
Work Humidity : | 0-85% RH (no coagulation) |
Preheating time : | 1 min |
Signal Output : | 4-20 mA (two-wires), RS485 |
Capacity : | 0.5A/12VAC or 1A/30VDC |
Repeat : | <+2%FS |
Operating Current : | 20-200mA |
Zero Drift : | <+2%FS/6h |
Span Drift : | <+5%FS/6h |
Transmission Distance : | 4~20mA<100m, RS485<1000m |
Housing Color : | Yellow |
Weight : | <2000g |
Explosion-proof grade : | Ex d ll CT6 |
Cable : | > RVVP9*0.3 mm2 |
Protection Grade : | IP65 |
Electrical Interface (thread) : | M26*P2.0 (explosion-proof connector: M26 M20)t |
Power consumption : | <3W |
Material of housing : | Cast Aluminum |
Display Information:
● Gas concentration
● Gas type
● Measurement unit
● Instrument status
Sensor Configuration:
● Independent air chamber
● No sensor replacement required
● Automatic identification of key sensor parameters
Protection Functions:
● Protection against high gas concentration exposure
Measurement Units:
● Gas concentration displayed in:
■ Parts per million (ppm)
■ Milligrams per cubic meter (mg/m3) – selectable option
Operation:
● Infrared remote controller operation
● Equipped with a 16-bit ADC acquisition chip
Circuit Design:
● Four-layer circuit board design for high anti-interference ability
Certification:
● Ex-proof certificate
● Ex-proof grade: Exd II CT6
Remote Diagnostic Feature
This feature allows connectivity through a 4G SIM card, Wi-Fi, and Ethernet for real-time measurements. It helps to take corrective action based on the readings.
TVOC detectors are commonly used to monitor indoor air quality, in factories, and for safety in the environment.